Abstract. According to the European directives and international standards, the noise emission of noise sources may be declared. The prime descriptor is an A-weighted emission sound pressure level and its value determines the following step in the noise emission declaration. If an A-weighted emission sound pressure level value is greater than 85dB (A), then the sound power level may be declared. Today measurements of noise emission levels are carried out according to the ISO 11200-series in either specially defined test rooms or in ordinary environmental one, where the sound pressure levels must be correct. In this paper, the results of the investigation of a new method approximating the noise emission level by the sound intensity level have been presented. Because of the sound field reactivity, sound field diffusivity, noise source directivity and measurement probe directivity's influence on the measurement results, the results of investigation of the mentioned factors will be also presented.
Key Words: Noise emission, noise source, sound intensity, measurement

NOVI METOD ZA DEKLARISANJE EMISIJE BUKE
ZASNOVAN NA MERENJU INTENZITETA ZVUKA
Emisija izvora buke mora se deklarisati u skladu sa zahtevima evropskih direktiva i međunarodnim standardima. Primarni parametar koji je potrebno odrediti je A-ponderisani nivo buke a njegova vrednosti određuje sledeći korak u proceduri deklarisanja emisije buke. Ako je A-ponderisani nivo emisije buke veći od 85dB(A) neophodno je deklarisati i nivo zvučne snage izvora buke. Nivo emisije buke određuje se u skladu sa serijom međunarodnih standarda ISO 11200 u ijalno definisanim mernim prostorijama ili u običnom okruženju kada se izmereni nivo zvučnog pritiska mora korigovati. U radu su prikazani rezultati istraživanja nove metode kojom se aproksimira nivo emisije buke izvora nivoom intenziteta zvuka. Prikazan je i uticaj različitih faktora na preciznost mernih rezultatata kao što su: difuznost zvučnog polja, reaktivnost zvučnog polja, direktivnost izvora buke i direktivnost merne sonde za intenzitet zvuka.
Ključne reči: Emisija buke, izvor buke, intenzitet zvuka, merenje.