Vol.2, No 5, 2005 pp. 401 - 407
UDC 691.16

INVESTIGATION OF EMULSIFIED HYDROUS
EPOXY SYSTEMS
Saša Zlatković1, Ljiljana Rašković2,
Goran Nikolić3, Jakov Stamenković3
1Pharmaceutical & Chemical Industry "Zdravlje-Pharmaco", Leskovac, 199 Vlajkova St.
2Dyes and Lacquers Industry "Pomoravlje" Niš, 129 Bulevar 12. februar
3Faculty of Technology, Leskovac, 124 Bulevar oslobodjenja

Abstract. The hard resin was dispersed in water EP 384 W (Solutia-Vianova, Austria) and cross-linked with aliphatic polyaminaduct hardener EH 623 W (Solutia-Vianova, Austria) and distilled water in a stoichiometric ratio of 50:10:20, respectively.
The degree of the epoxy resin cross-linking and the quantity of unreacted epoxy groups have been monitored by the FTIR spectroscopic method. The optimal time of total cross-linking as the measure of the degree of cross-linking was determined by indirect measuring of the film hardness (JUS.H.C8.055).
Key Words: Epoxy system, degree of cross-linking, FTIR spectroscopic method, film hardness

ISPITIVANJE EMULGOVANIH VODENIH EPOKSI SISTEMA
Čvrsta smola dispergovana u vodi EP384W (Solutia-Vianova, Austrija), umrežavana je alifatičnim poliaminoadukt umreživačem EH623W (Solutia-Vianova, Austrija) i destilovanom vodom, u stehiometrijskom odnosu 50 : 10 : 20.
Stepen umreženosti epoksi smole i kvantitet neprereagovalih epoksi grupa praćeni su metodom FTIR spektroskopije. Optimalno vreme potpunog umrežavanja, kao mera stepena umreženosti, određivano je merenjem tvrdoće filma indirektnim putem (JUS.H.C8.055).
Ključne reči: Epoksi sistem, stepen umreženosti,FTIR spektroskopija, tvrdoća filma.