Vol. 6, No 2, 2008 pp. 115 - 123
UDC 796.42
Scientific Paper

PROBLEMS IN DETERMINATION OF THE VENTILATORY THRESHOLD BASED 
ON THE RESPIRATORY EXCHANGE RATIO IN HIGH-LEVEL ATHLETES

Stanislav Tzvetkov1, Peter Bonov2, Daniela Dasheva2
1Department of Sports Medicine, National Sports Academy, St. grad, 1710 Sofia, Bulgaria,
2National Sports Academy, St. grad, 1710 Sofia, Bulgaria,
E-mail: st.tzvetkov@gmail.com, bonov@nsa.bg, dani_dash@yahoo.com

Abstract. As an alternative to the invasive lactate anaerobic threshold determination, a number of methods for detection of the ventilatory threshold (VT) are applied – using the respiratory exchange ratio (VTRER=1.0), the breakpoint of the nonlinear increase of the ventilatory equivalent for oxygen (VTEqO2) and the Vco2 versus Vo2 curve (VTV-slope). Some researchers identify a respiratory compensation point (RCP); others question the accuracy of the VTRER method. We aimed to compare the results for VTRER=1.0, VTEqO2, VTV-slope and RCP in 18 high-level male athletes who are involved in aerobic sports. In the One-Way ANOVA test a significant difference was demonstrated between the corresponding values of VO2 and WC (F = 7.95 and F = 14.53; p < 0.05) in the pairs VTV-slope - VTRER=1.0, VTV-slope - RCP, VTEqO2 - VTRER=1.0 and VTEqO2 - RCP. The multiple pair-wise comparison analysis for VO2 and WC revealed a lack of statistically acceptable interchangeability of VTRER=1.0 with VTV-slope and VTEqO2.
Key words:  respiratory exchange gases, ventilatory threshold, comparative analysis

PROBLEM ODREĐIVANJA VENTILATORNOG PRAGA BAZIRANOM NA 
RASPONU RESPIRATORNE RAZMENE KOD VRHUNSKIH SPORTISTA
Kao alternativu invazivniom određivanju laktatnog anaerobnog praga, brojne metode detekcije ventilatornog praga (VT) su korišćene – upotrebom raspona respiratorne razmene (VTRER=1.0), tačka prekida nelinearnog povećanja ventilatornog ekvivalenta za kiseonik (VTEqO2) i kriva Vco2 u odnosu na Vco2 (VTV-slope). Neki autori identifikuju tačku respiratorne kompenzacije (RCP), drugi postavljaju pitanje tačnosti VTRER metode. Cilj je bio da se uporede rezultati za VTRER=1.0, VTEqO2, VTV-slope i RCP kod 18 muškaraca, visoko kvalitetnih sportista iz aerobnih sportova. U One-Way ANOVA testu značajnosti razlika je pokazano da postoje uzajamne vrednosti VO2 i radnog kapaciteta (F = 7,95 and F = 14,53; p < 0,05) u paru VTV-slope - VTRER=1.0, VTV-slope - RCP, VTEqO2 - VTRER=1.0 i VTEqO2 - RCP. Višestruka parovna komparativna analiza za VO2 i radni kapacitet otkrila je nedostatak prihvatljive statističke uzajamnosti VTRER=1.0 sa VTV-slope i VTEqO2.
Ključne reči: respiratorna razmena gasova, ventilatorni prag, comparativna analiza